MIT CMS Tier-2 Facility

Webpage: http://www.cmsaf.mit.edu

With CMS VO LCG certificate submit jobs to ce01.cmsaf.mit.edu.
Note that this is an OSG site (not LCG!).
The main CMS software installation is at /net/hisrv0001/app/cmsprod.

Informations from Christof:

The CatalogFiles of the output of the last data production can be found in
/net/pstore02/d00/rolandc/CatalogFiles
and
/net/pstore02/d00/rolandc/dCacheCatalogFiles
for the dCache version respectively.

Minimal pT for the multijet events is 7 GeV.

Pythia Multijet (unquenched)

Centrality Events
central POOL_Catalog.EVD.hi_Hit398_2_g133.hi05_hydjet_x3_b0_pt07.xml
POOL_Catalog.META.hi05_hydjet_x3_b0_pt07.xml
10k
semi-central POOL_Catalog.EVD.hi_Hit398_2_g133.hi05_hydjet_x3_b9_pt07.xml
POOL_Catalog.META.hi05_hydjet_x3_b9_pt07.xml
100k
peripheral POOL_Catalog.EVD.hi_Hit398_2_g133.hi05_hydjet_x3_b12_pt07.xml
POOL_Catalog.META.hi05_hydjet_x3_b12_pt07.xml
1M

Pyquen Multijet (quenched)

Centrality Events
central POOL_Catalog.EVD.hi_Hit398_2_g133.hi05_hydjet_x4_b0_pt07.xml
POOL_Catalog.META.hi05_hydjet_x4_b0_pt07.xml
10k
semi-central POOL_Catalog.EVD.hi_Hit398_2_g133.hi05_hydjet_x4_b9_pt07.xml
POOL_Catalog.META.hi05_hydjet_x4_b9_pt07.xml
100k
peripheral POOL_Catalog.EVD.hi05_hydjet_x4_b12_pt07.hi_Hit398_2_g133.xml
POOL_Catalog.META.hi05_hydjet_x4_b12_pt07.xml
1M

Pure Hydro

Centrality Events
central PoolCatalogHydjetX0B0P07.xml 1k
semi-central PoolCatalogHydjetX0B9P07.xml 10k
peripheral PoolCatalogHydjetX0B12P07.xml 100k

Single QCD dijet files

Generator Centrality
Unquenched Pythia   PoolCatalogPythia50.xml PoolCatalogPythia70.xml
PoolCatalogPythia100.xml PoolCatalogPythia130.xml
Quenched Pyquen central PoolCatalogPyquen50_b0.xml PoolCatalogPyquen70_b0.xml
PoolCatalogPyquen100_b0.xml PoolCatalogPyquen130_b0.xml
Quenched Pyquen semi-central PoolCatalogPyquen50_b9.xml PoolCatalogPyquen70_b9.xml
PoolCatalogPyquen100_b9.xml PoolCatalogPyquen130_b9.xml
Quenched Pyquen peripheral PoolCatalogPyquen50_b12.xml PoolCatalogPyquen70_b12.xml
PoolCatalogPyquen100_b12.xml PoolCatalogPyquen130_b12.xml

Here 50, 70, 100 and 130 refer to pT ranges of 50-60, 70-80, 100-110 and 130-140 GeV, respectively. Each contains 20k events.

-- FerencSikler - 02 Mar 2006

Edit | Attach | Watch | Print version | History: r3 < r2 < r1 | Backlinks | Raw View | Raw edit | More topic actions
Topic revision: r3 - 2007-11-11 - FerencSikler
 
This site is powered by the TWiki collaboration platform Powered by Perl This site is powered by the TWiki collaboration platformCopyright &© by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback